Welcome to Railway Signalling & Communication Engineering, Today is 中文

Railway Signalling & Communication Engineering ›› 2022, Vol. 19 ›› Issue (5): 90-95.DOI: 10.3969/j.issn.1673-4440.2022.05.018

Previous Articles     Next Articles

Analysis of LKJ Correction Failure Caused by Carrier Frequency Leakage of Track Signal on Handan-Jinan Railway

 Huang Tiantian1,  Li Xinjian2,  Liu Mingyuan1   

  1. 1. Beijing Huatie Information Technology Co., Ltd., Beijing    100081, China
    2. Jinan Signaling & Communication Depot, China Railway Jinan Group Co., Ltd., Jinan    250001, China
  • Received:2021-03-31 Revised:2022-03-25 Online:2022-05-25 Published:2022-05-25

邯济线轨道信号载频泄漏导致LKJ过机校正不良的分析

黄天天1,李新健2,刘明源1   

  1. 1.北京华铁信息技术有限公司,北京 100081;
    2.中国铁路济南局集团有限公司济南电务段,济南 250001
  • 作者简介:黄天天(1983—),男,工程师,本科,主要研究方向:铁路信号控制,邮箱:tian9045516@163.com

Abstract: In the construction of signal equipment for Handan-Jinan Railway expansion and reconstruction, the distance is not accurate due to that the locomotive directly passed over the signal without distance correction by LKJ-2000. In order to find out the reason, this paper analyzes the principle, processing mode and procedure of distance correction of LKJ-2000 when locomotive passing over signal, which can provide reference and analysis method for the distance correction failure of LKJ when passing over signal.

Key words: LKJ, passing over signal without distance correction, track signal, carrier frequency leakage

摘要: 在邯济线扩能改造信号设备施工过程中,LKJ-2000型列车运行监控记录装置过机不校,导致数据距离不准的情况。研究LKJ-2000型列车运行监控记录装置过机校正原理,分析过机校正的处理方式和过程,并查找出造成邯济线过机不校的原因,从而对分析LKJ过机校正不良提供参考和思路。

关键词: 列车运行监控记录装置, 过机不校, 轨道信号, 载频泄漏

CLC Number: