Railway Signalling & Communication Engineering ›› 2021, Vol. 18 ›› Issue (1): 95-100,108.DOI: 10.3969/j.issn.1673-4440.2021.01.019
Previous Articles Next Articles
Liu Guopeng
Received:
Revised:
Online:
Published:
刘国鹏
Abstract: The small rail voltage of ZPW-2000A track circuit reflects the state of tuning zone. Firstly, there are many reasons for daily fluctuation, which makes it difficult to find the fault on site; secondly, when the fault occurs, the attention paid to the small rail voltage analysis is not enough, which leads to the fault finding detour. In this paper, combined with field experience and cases, using the centralized signal monitoring data and curves, the causes of small rail voltage fluctuation and abnormal are analyzed.
Key words: centralized signal monitoring, small rail voltage, fluctuation, analysis
摘要: ZPW-2000A轨道电路小轨电压反映调谐区的状态。一是日常出现的波动原因较多,造成现场不容易查找;二是发生故障时,对小轨电压关注分析不够,造成查找故障走弯路。结合现场经验及案例,利用信号集中监测数据及曲线,分析小轨电压波动、异常成因。
关键词: 信号集中监测、小轨电压、波动异常、分析
CLC Number:
U284.2
Liu Guopeng. Judgment and Analysis of Small Rail Voltage Fluctuation of ZPW-2000A Track Circuit[J]. Railway Signalling & Communication Engineering, 2021, 18(1): 95-100,108.
刘国鹏. ZPW-2000A轨道电路小轨电压异常判断分析[J]. 铁路通信信号工程技术, 2021, 18(1): 95-100,108.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://rsce.crscd.com.cn//EN/10.3969/j.issn.1673-4440.2021.01.019
https://rsce.crscd.com.cn//EN/Y2021/V18/I1/95